258S004-05
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
258S004-05
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Type
encased
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
8.985 inches minimum and 9.015 inches maximum
-
Operating Current Rating Per Function In Amps
25.0 1st radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
6.735 inches minimum and 6.765 inches maximum
-
Operating Current Rating Per Function In Amps
25.0 2nd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Mounting Facility Type And Quantity
8 unthreaded hole
-
Functional Terminal Type And Quantity
2 wire lead output 2nd function
-
Operating Voltage Rating And Type Per Function
600.0 volts dc 1st radio interference 1st function
-
Unthreaded Mounting Hole Diameter
0.296 inches nominal
-
Overall Height
3.090 inches minimum and 3.150 inches maximum
-
Overall Width
11.810 inches maximum
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Operating Voltage Rating And Type Per Function
600.0 volts dc 2nd radio interference 2nd function
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Functional Terminal Type And Quantity
2 threaded stud input 1st function
-
Body Length
5.690 inches minimum and 5.810 inches maximum
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Body Width
9.940 inches minimum and 10.060 inches maximum
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Overall Length
7.720 inches minimum and 7.780 inches maximum