532335-66

Circuit Breakers

CIRCUIT BREAKER

532335-66

5925-01-130-9489

5925 - Circuit Breakers

Raytheon Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.500 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.490 inches minimum and 1.510 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.053 inches minimum and 2.073 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic

  • Terminal Type And Quantity

    2 threaded stud

  • Thread Series Designator

    unc

  • Frequency In Hertz

    60.0

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.540 inches minimum and 2.580 inches maximum

  • Boss Height

    0.110 inches minimum and 0.130 inches maximum

  • Fragility Factor

    moderately rugged

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Unpackaged Unit Weight

    4.000 ounces

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct and 3.000 maximum at 200 pct

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...