P-8-9152

Switches

SWITCH,PRESSURE

P-8-9152

5930-01-132-3062

5930 - Switches

Lennox Industries Inc

SWITCH,PRESSURE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Contact Load Current Rating

    2.0 amperes resistive load third voltage

  • Contact Voltage Rating In Volts

    28.0 ac at sea level third voltage

  • Nonpile-Up Contact Arrangement

    1 pole, single throw, normally open, momentary action

  • Mounting Method

    line

  • Width Across Flats

    0.563 inches nominal

  • Contact Load Current Rating

    2.0 amperes resistive load first voltage

  • Thread Series Designator

    unf single pressure connection

  • Contact Load Current Rating

    2.0 amperes resistive load second voltage

  • Frequency In Hertz

    60.0 second voltage

  • Contact Voltage Rating In Volts

    120.0 ac at sea level second voltage

  • Inside Diameter

    0.438 inches nominal single connection

  • Contact Load Current Rating

    2.0 amperes resistive load fourth voltage

  • Frequency In Hertz

    60.0 third voltage

  • Frequency In Hertz

    60.0 first voltage

  • Contact Stimulus Rating

    30.00 actuation point nominal pounds per square inch gage and 10.00 deactuation point nominal pounds per square inch gage

  • Nominal Thread Size

    0.438 inches single pressure connection

  • Hazardous Locations/Environmental Protection

    waterproof

  • Style Designator

    cylindrical

  • Contact Voltage Rating In Volts

    240.0 ac at sea level first voltage

  • Overall Length

    1.976 inches nominal

  • Contact Adjustability

    actuation point not adjustable and deactuation point not adjustable

  • Pressure Connector Type

    swivel nut, flare, threaded internal single connection

  • Media For Which Designed

    gas

  • Contact Voltage Rating In Volts

    28.0 dc at sea level fourth voltage

  • Pressure Switch Type

    gage

  • Body Length

    1.876 inches nominal

  • Overall Diameter

    0.813 inches nominal

  • Terminal Type

    wire lead

  • Thread Class

    2b single pressure connection

  • Proof Pressure

    400.00 pounds per square inch gage

  • Operating Temp Rating

    -20.0 deg fahrenheit minimum and 150.0 deg fahrenheit maximum

  • Contact Action Stimulus

    increase

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...