CD2-A3-U-100-240-1

Circuit Breakers

CIRCUIT BREAKER

CD2-A3-U-100-240-1

5925-01-133-1594

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    5.768 inches minimum and 5.832 inches maximum

  • End Item Identification

    item is used in an electrical power distribution panel on a 32 ft. coast guard vessel

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Mounting Slot Width

    0.164 inches nominal

  • Body Width

    2.038 inches minimum and 2.102 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.718 inches minimum and 2.782 inches maximum

  • Mounting Surface To Terminal End Distance

    3.172 inches minimum and 3.296 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole and 4 slot

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    35.000 minimum at 200 pct and 100.000 maximum at 200 pct

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    4 threaded stud

  • Thread Series Designator

    unc

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    2 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay

  • Trip Release Method

    magnetic-hydraulic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac

  • Arc Quenching Method

    magnetic blowout

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.016 inches minimum and 1.036 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.016 inches minimum and 1.036 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    3.515 inches minimum and 3.579 inches maximum

  • Body Height

    2.828 inches nominal

  • Body Style

    multipole-multiple actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...