0094-3

Circuit Breakers

CIRCUIT BREAKER

0094-3

5925-01-133-2645

5925 - Circuit Breakers

Eltech Research Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Method

    magnetic-hydraulic all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Body Length

    2.000 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.130 inches nominal

  • Case Material

    plastic

  • External Actuator Linkage Arrangement

    one and two linked

  • Body Width

    1.500 inches nominal

  • Terminal Type And Quantity

    4 quick disconnect, male

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and fungus resistant and moisture resistant and humidity resistant and vibration resistant

  • Manual Actuator Type And Quantity

    2 toggle

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    1.890 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Length

    1.560 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...