11462223

Circuit Breakers

CIRCUIT BREAKER

11462223

5925-01-133-8449

5925 - Circuit Breakers

Wildwood Electronics Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations or 400.0 all locations

  • Body Width

    1.562 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Body Length

    1.937 inches maximum

  • Ultimate Trip Time Per Pole In Seconds

    3.000 minimum all locations and 60.000 maximum all locations

  • Nominal Thread Size

    0.380 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Case Material

    ceramic

  • Mounting Facility Type And Quantity

    2 threaded bushing w/panel seal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    9.000 maximum at 200 pct all locations and 3.000 minimum at 135 pct all locations and 1.750 maximum at 400 pct all locations and 0.600 maximum at 600 pct all locations and 60.000 maximum at 135 pct all locations and 0.500 minimum at 200 pct all locations

  • ~1

    and 0.100 maximum at 800 pct all locations

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Terminal Type And Quantity

    3 wire hook

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...