MIL-C-39019/1

Circuit Breakers

CIRCUIT BREAKER

MIL-C-39019/1

5925-01-135-1195

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    single pole type

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Case Material

    metal

  • Mounting Surface To Terminal End Distance

    1.669 inches minimum and 1.700 inches maximum

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    250.0 milliamperes ac and 250.0 milliamperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and 50.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac and 500.0 dc

  • Trip Release Method

    magnetic

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct and 9.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Frequency In Hertz

    400.0

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    2 wire hook

  • Specification/Standard Data

    81349-mil-c-39019/1 government specification

  • Body Length

    1.531 inches minimum and 1.562 inches maximum

  • Body Width

    0.594 inches minimum and 0.625 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches minimum and 0.906 inches maximum

  • Features Provided

    high inrush protection

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.375 inches

  • Test Data Document

    81349-mil-c-39019 specification

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...