168710003

Switches

SWITCH,THERMOSTATIC

168710003

5930-01-135-5132

5930 - Switches

L3 Communications Elac Nautik Gmbh

SWITCH,THERMOSTATIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Specification/Standard Data

    81349-mil-s-24236/20 government specification

  • Contact Action Stimulus

    decrease

  • Contact Voltage Rating In Volts

    28.0 dc at sea level second voltage

  • Contact Adjustability

    deactuation point not adjustable and actuation point not adjustable

  • Operating Temp Rating

    -10.0 deg fahrenheit minimum and 250.0 deg fahrenheit maximum

  • ~1

    degrees fahrenheit

  • ~1

    data on certain environmental and performanc

  • Contact Stimulus Rating

    10.00 actuation point nominal degrees fahrenheit and 15.00 deactuation point maximum degrees fahrenheit and 2.00 differential point minimum degrees fahrenheit and 12.00 deactuation point minimum degrees fahrenheit and 5.00 differential point maximum

  • Test Data Document

    81349-mil-s-24236 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Overall Length

    0.956 inches nominal

  • Style Designator

    disc

  • Mounting Method

    clamp

  • Nonpile-Up Contact Arrangement

    1 pole, single throw, normally open, momentary action

  • End Item Identification

    6665-01-081-8140

  • Features Provided

    hermetically sealed case

  • Terminal Type

    tab, solder lug

  • Body Diameter

    0.660 nominal centimeters

  • Temp Sensing Element Type

    internal sensor

  • Overall Height

    0.300 inches maximum

  • Contact Load Current Rating

    2.0 amperes resistive load second voltage and 1.0 amperes inductive load second voltage and 1.0 amperes lamp load second voltage

  • Media For Which Designed

    gas or liquid

  • Contact Voltage Rating In Volts

    115.0 ac at sea level first voltage

  • Frequency In Hertz

    60.0 first voltage

  • Contact Load Current Rating

    2.0 amperes resistive load first voltage and 1.5 amperes inductive load first voltage and 0.5 amperes lamp load first voltage

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...