UHL10-200
Capacitors
CAPACITOR,FIXED,ELECTROLYTIC
UHL10-200
CAPACITOR,FIXED,ELECTROLYTIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-c-39018 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performanc
-
Reliability Failure Rate Level In Percent
1.0000
-
Dc Leakage At Reference Temp
8.000 microamperes
-
Capacitance Value Per Section
10.000 microfarads single section
-
Case Material
metal
-
Equivalent Series Resistance At Reference Temp In Ohms
13.26
-
Overall Length (Non-Core)
1.578 inches maximum
-
Nonderated Operating Temp
-55.0 deg celsius minimum and 85.0 deg celsius maximum
-
Body Style
w/o mtg facilities, axial terminals
-
Nonderated Continuous Voltage Rating And Type Per Section
250.0 dc single section
-
Overall Height (Non-Core)
0.383 inches nominal
-
Terminal Diameter
0.032 inches nominal
-
Tolerance Range Per Section
-10.00/+30.00 percent single section
-
Terminal Type And Quantity
2 uninsulated wire lead
-
Body Length
1.578 inches maximum
-
Reliability Indicator
established
-
Body Diameter
0.383 inches nominal
-
Overall Width (Non-Core)
0.383 inches nominal
-
Terminal Length
1.500 inches nominal
-
Terminal Surface Treatment
solder
-
Impedance At Minimum Operating Temp In Ohms
300.0
-
Schematic Diagram Designator
electrode(s) grounded to case, w/gnd terminal
-
Capacitive Electrode Material
aluminum
-
Specification/Standard Data
81349-mil-c-39018/1 government specification
-
Dc Leakage At Maximum Operating Temp
48.0 microamperes
-
Case Insulation Material
plastic
-
Electrical Polarization
polarized