Technical Characteristics

  • Bushing Length

    0.203 inches minimum and 0.235 inches maximum

  • Body Length

    5.984 inches minimum and 6.016 inches maximum

  • Body Width

    2.984 inches minimum and 3.016 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.484 inches minimum and 1.516 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Switch Terminal Type

    wire lead

  • Precious Material

    silver

  • Body Style

    2b multipole-single actuator type

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    5.109 inches minimum and 5.141 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.578 inches minimum and 4.610 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    3.984 inches minimum and 4.016 inches maximum

  • Pole Quantity

    2

  • Storage Type

    general purpose warehouse

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Release Characteristic

    instantaneous all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Switch Location And Position Designation

    internal between pole one and two

  • Inclosure Protection Type For Which Designed

    fungus proof

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Switch Current Rating And Type In Amps

    15.0 ac and 0.25 dc

  • Switch Voltage Rating And Type In Volts

    240.0 ac and 250.0 dc

  • Frequency In Hertz

    60.0

  • Precious Material And Location

    terminal and contact surfaces silver

  • Terminal Type And Quantity

    4 compression

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...