FAL3600311M

Circuit Breakers

CIRCUIT BREAKER

FAL3600311M

5925-01-136-9575

5925 - Circuit Breakers

Schneider Electric Usa Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    35.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct all locations

  • Case Material

    plastic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Body Width

    4.469 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.125 inches nominal

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Terminal Type And Quantity

    3 clip and 3 compression

  • Body Height

    3.000 inches nominal

  • Actuator Position Designation

    at pole two

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac all locations

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    5.125 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Boss Height

    0.125 inches nominal

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +8.0/+28.0 ac all locations

  • Body Length

    6.000 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...