Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Width

    1.320 inches maximum

  • Body Style

    multipole-single actuator type

  • Internal Trip Release Configuration

    series trip second location

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    4 tab, solder lug

  • Boss Height

    0.220 inches minimum and 0.280 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    5.0 dc first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes dc first location

  • Internal Trip Release Configuration

    relay trip first location

  • Case Material

    plastic

  • Mounting Facility Type And Quantity

    2 clip

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Pole Quantity

    2

  • Body Length

    1.970 inches minimum and 2.030 inches maximum

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Unpackaged Unit Weight

    2.600 ounces

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc second location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 dc second location

  • Body Height

    1.770 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.595 inches minimum and 0.655 inches maximum

  • Trip Release Method

    magnetic all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...