T11-1-10.0A-02-31A-V

Circuit Breakers

CIRCUIT BREAKER

T11-1-10.0A-02-31A-V

5925-01-138-4059

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Special Handling Feature

    magnetic

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Mounting Surface To Terminal End Distance

    1.540 inches nominal

  • Reset Method

    manual

  • Nominal Thread Size

    0.500 inches

  • Actuator Position Designation

    at pole one

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Body Length

    1.375 inches nominal

  • Bushing Length

    0.468 inches nominal

  • Pole Quantity

    1

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct single location and 2.000 maximum at 200 pct single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Body Width

    0.680 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 single location

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Style

    single pole type

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location and 10.0 amperes dc single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.395 inches nominal

  • Thread Series Designator

    un

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 32.0 dc single location

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...