1600-037-15007

Circuit Breakers

CIRCUIT BREAKER

1600-037-15007

5925-01-138-4930

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

  • Storage Type

    general purpose warehouse

  • Manual Actuator Type And Quantity

    1 push button

  • Body Length

    1.380 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct single location and 30.000 maximum at 200 pct single location

  • Nominal Thread Size

    0.438 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 50.0 dc single location

  • Thread Quantity Per Inch

    28

  • Case Material

    plastic

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Mounting Surface To Terminal End Distance

    1.660 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    77.0 deg fahrenheit nominal single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.840 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location and 15.0 amperes dc single location

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Style

    single pole type

  • Frequency In Hertz

    60.0 single location

  • Thread Series Designator

    unef

  • Body Width

    0.560 inches nominal

  • Bushing Length

    0.500 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...