MIL-C-17588

Circuit Breakers

CIRCUIT BREAKER

MIL-C-17588

5925-01-138-9593

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Specification/Standard Data

    81349-mil-c-17588 government specification

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac single location and 125.0 dc single location

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac single location and 30.0 amperes dc single location

  • Storage Type

    general purpose warehouse

  • Body Height

    2.312 inches nominal

  • Actuator Function

    trip-reset

  • Mounting Slot Width

    0.094 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Test Data Document

    81349-mil-c-17588 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 210.000 maximum at 200 pct single location

  • Terminal Type And Quantity

    1 quick disconnect, male and 1 compression

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal single location

  • Trip Release Method

    thermal-magnetic single location

  • Body Length

    3.500 inches nominal

  • Boss Height

    0.188 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    0.969 inches nominal

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Mounting Facility Type And Quantity

    1 slot

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 2500.0 dc single location

  • Trip Release Characteristic

    instantaneous single location and time delay single location

  • Case Material

    plastic

  • ~1

    data on certain environmental and performanc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...