315C574G18 WITH 452D377G17
Circuit Breakers
CIRCUIT BREAKER
315C574G18 WITH 452D377G17
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
20000.0 ac second location and 15000.0 dc second location
-
Maximum Continuous Load Current Rating Per Pole
250.0 amperes ac all locations and 250.0 amperes dc all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
100000.0 ac third location
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud
-
Fragility Factor
moderately rugged
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
9.875 inches nominal
-
Trip Release Characteristic
instantaneous all locations
-
Mounting Surface To Terminal End Distance
9.281 inches nominal
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Reset Method
manual
-
Frequency In Hertz
400.0 first location
-
Features Provided
adjustable trip release
-
Center To Center Distance Between Terminals Parallel To Length
9.875 inches nominal
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Mounting Facility Type And Quantity
4 threaded hole
-
Thread Quantity Per Inch
32
-
Arc Quenching Method
air
-
Trip Release Method
magnetic all locations
-
Center To Center Distance Between Terminals Parallel To Width
3.000 inches nominal
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Internal Trip Release Configuration
series trip first location
-
Body Width
9.000 inches nominal
-
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac first location and 250.0 dc first location
-
Actuator Position Designation
at pole two
-
Body Style
multipole-single actuator type
-
Internal Trip Release Configuration
series trip second location
-
Boss Height
0.250 inches nominal
-
Manual Actuator Type And Quantity
1 toggle
-
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac second location and 250.0 dc second location
-
Adjustable Trip Setting Current Range Per Pole In Amps
+910.0/+1560.0 ac third location
-
Operating Voltage Type And Rating Per Pole In Volts
450.0 ac third location
-
Frequency In Hertz
400.0 second location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.000 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
60.0 third location
-
Body Length
11.000 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
20000.0 ac first location and 15000.0 dc first location
-
Internal Trip Release Configuration
shunt trip third location
-
Nominal Thread Size
0.250 inches