AM4-Z111-1

Circuit Breakers

CIRCUIT BREAKER

AM4-Z111-1

5925-01-139-3865

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    8 threaded stud

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Body Width

    2.990 inches minimum and 3.010 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • End Item Identification

    f16aircombfit

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Pole Quantity

    4

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Circuit Protection Type

    overcurrent

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    4 toggle

  • External Actuator Linkage Arrangement

    one,two,three,and four linked

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct and 70.000 maximum at 200 pct

  • Frequency In Hertz

    60.0

  • Unpackaged Unit Weight

    12.500 ounces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...