1057-1324
Coils and Transformers
TRANSFORMER,POWER
1057-1324
Technical Services Laboratory Inc
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
230.00 ac volts nominal single component single primary
-
Frequency Rating
50.0 hertz minimum single component and 500.0 hertz maximum single component
-
Input-Output Phase Relationship
single phase to single phase single component
-
Reliability Indicator
not established
-
Terminal Type And Quantity
5 wire lead
-
Winding Power Rating
150.0 volts-amperes single component single secondary
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Winding Operating Voltage
90.00 ac volts nominal single component single secondary
-
Winding Operating Current
1.7 amperes ac nominal single component single secondary