Technical Characteristics

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Center To Center Distance Between Terminals Parallel To Width

    0.610 inches minimum and 0.640 inches maximum

  • Case Material

    metal

  • Thread Series Designator

    unef

  • Unpackaged Unit Weight

    3.600 ounces

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Nominal Thread Size

    0.375 inches

  • Internal Trip Release Configuration

    series trip

  • Trip Release Method

    magnetic

  • Circuit Protection Type

    overcurrent

  • Special Handling Feature

    magnetic

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Pole Quantity

    2

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Nonturn Device Diameter

    0.235 inches minimum and 0.265 inches maximum

  • Nonturn Device Length

    0.130 inches nominal

  • Nonturn Device Radius

    0.610 inches minimum and 0.640 inches maximum

  • Terminal Type And Quantity

    4 wire hook

  • Actuator Position Designation

    between pole one and two

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Trip Release Characteristic

    instantaneouss

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Maximum Continuous Load Current Rating Per Pole

    1.500 amperes dc

  • Thread Quantity Per Inch

    32

  • Arc Quenching Method

    magnetic blowout

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    0.860 inches minimum and 0.890 inches maximum

  • Body Width

    1.281 inches maximum

  • Body Length

    1.562 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Thread Pitch Diameters

    p0.3503/p0.3537 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...