Technical Characteristics

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Nonturn Device Width

    0.110 inches nominal

  • Nonturn Device Location

    at 12 oclock

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Body Length

    1.260 inches nominal

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Thread Pitch In Millimeters

    1.75

  • Center To Center Distance Between Terminals Parallel To Length

    0.900 inches nominal

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Nonturn Device Length

    0.060 inches nominal

  • Nominal Thread Size

    12.0 millimeters

  • Bushing Length

    0.260 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    12.000 minimum at 200 pct single location and 80.000 maximum at 200 pct single location

  • Frequency In Hertz

    400.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac single location and 70.0 amperes dc single location

  • Body Style

    single pole type

  • Thread Series Designator

    iso m

  • Nonturn Device Radius

    0.370 inches nominal

  • Terminal Type And Quantity

    2 tab w/screw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 single location

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.520 inches maximum

  • Body Width

    0.730 inches nominal

  • Trip Release Ambient Temp Rating

    70.0 deg fahrenheit nominal single location

  • Reset Method

    manual

  • Unpackaged Unit Weight

    2.300 ounces

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location and 2000.0 dc single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and corrosion resistant and humidity resistant

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...