APGN-6-7984-1

Circuit Breakers

CIRCUIT BREAKER

APGN-6-7984-1

5925-01-142-0330

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct single location and 8.000 maximum at 200 pct single location

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Reset Method

    manual

  • Nominal Thread Size

    0.500 inches

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Body Width

    0.750 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes dc single location

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Nonturn Device Location

    at 12 oclock

  • Trip Release Method

    magnetic-hydraulic single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Unpackaged Unit Weight

    3.000 ounces

  • Thread Series Designator

    un

  • Nonturn Device Radius

    0.656 inches nominal

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Case Material

    plastic

  • Nonturn Device Length

    0.130 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Pole Quantity

    1

  • Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Thread Pitch Diameters

    +0.4752/+0.4787 inches

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Bushing Length

    0.625 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Body Style

    single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...