179005P11

Circuit Breakers

CIRCUIT BREAKER

179005P11

5925-01-142-2178

5925 - Circuit Breakers

Bae Systems Information And

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    12a single pole type

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Mounting Surface To Terminal End Distance

    1.875 inches minimum and 1.885 inches maximum

  • Iii Arc Quenching Method

    magnetic blowout

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Body Width

    0.745 inches minimum and 0.755 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.555 inches minimum and 1.565 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.655 inches minimum and 1.665 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Boss Height

    0.125 inches minimum and 0.135 inches maximum

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.190 minimum at 200 pct and 1.900 maximum at 200 pct single location

  • Frequency In Hertz

    50.0 or 60.0 single location

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 tab, solder lug

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...