4310-003-15

Circuit Breakers

CIRCUIT BREAKER

4310-003-15

5925-01-143-3627

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location and 6000.0 dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Pole Quantity

    1

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.500 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.500 inches nominal

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Nominal Thread Size

    0.438 inches

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    1.343 inches maximum

  • Manual Actuator Type And Quantity

    1 push button

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Body Length

    0.781 inches maximum

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Body Width

    0.593 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Unpackaged Unit Weight

    25.0 grams

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Bushing Length

    0.045 inches nominal

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location and 15.0 amperes dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...