E-1935
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
E-1935
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
2.500 inches nominal
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Mounting Facility Type And Quantity
2 threaded hole
-
Operating Voltage Rating And Type Per Function
240.0 volts ac 1st radio interference 1st function
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Maximum Temp Rise
15.0 deg celsius
-
Body Height
1.750 inches nominal
-
Style Designator
rectangular terminal/terminals on two surfaces
-
Body Length
2.500 inches nominal
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.164 inches
-
Operating Voltage Rating And Type Per Function
240.0 volts ac 2nd radio interference 2nd function
-
Operating Current Rating Per Function In Amps
5.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Functional Terminal Type And Quantity
1 tab, solder lug ground 3rd function
-
Inclosure Type
hermetically sealed
-
Functional Terminal Type And Quantity
2 tab, solder lug output 2nd function
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Current Rating Per Function In Amps
5.0 2nd radio interference
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.500 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference