313-114

Coils and Transformers

TRANSFORMER,POWER

313-114

5950-01-145-2493

5950 - Coils and Transformers

Tempo Instrument Inc

TRANSFORMER,POWER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Winding Operating Voltage

    400.00 ac millivolts nominal single component 1st secondary

  • Winding Operating Current

    200.0 milliamperes ac maximum single component 2nd secondary

  • Criticality Code Justification

    feat

  • Winding Operating Current

    200.0 milliamperes ac maximum single component 4th secondary

  • Winding Operating Voltage

    1.00 ac volts nominal single component 4th secondary

  • Special Features

    weapon system essential

  • Winding Operating Voltage

    400.00 ac millivolts nominal single component 3rd secondary

  • Winding Operating Current

    1.0 amperes ac maximum single component 3rd secondary

  • Winding Power Rating

    0.4 volts-amperes single component 1st secondary

  • Winding Tap Location (Non-Core)

    err-070

  • Overall Length

    1.000 inches nominal

  • Maximum Operating Temp

    155.0 deg celsius

  • Overall Width

    0.610 inches maximum

  • Winding Power Rating

    0.4 volts-amperes single component 3rd secondary

  • Frequency Rating

    20.0 kilohertz maximum single component

  • Inclosure Type

    fully inclosed

  • Winding Power Rating

    2.0 volts-amperes single component 2nd secondary

  • Winding Function And Quantity

    1 primary single component and 4 secondary single component

  • Winding Power Rating

    2.0 volts-amperes single component 4th secondary

  • Winding Power Rating

    3.0 volts-amperes single component single primary

  • Reliability Indicator

    not established

  • Winding Operating Current

    1.0 amperes ac maximum single component 1st secondary

  • Mounting Method

    terminal single group

  • Input-Output Phase Relationship

    single phase to single phase single component

  • Overall Height

    0.770 inches nominal

  • Winding Operating Voltage

    1.00 ac volts nominal single component 2nd secondary

  • Winding Operating Current

    100.0 milliamperes ac nominal single component single primary

  • End Item Identification

    wsd: aircraft, hornet f/a-18

  • Winding Operating Voltage

    30.00 ac volts nominal single component single primary

  • Terminal Type And Quantity

    11 solder stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...