APL1112-8918-2
Circuit Breakers
CIRCUIT BREAKER
APL1112-8918-2
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Boss Height
0.150 inches nominal
-
Actuator Function
trip-reset
-
Body Width
3.015 inches maximum
-
Mounting Surface To Terminal End Distance
2.491 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct second location and 9.000 maximum at 200 pct second location
-
Thread Quantity Per Inch
32
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations and 1000.0 dc all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct first location and 9.000 maximum at 200 pct first location
-
Mounting Facility Type And Quantity
8 threaded hole
-
Frequency In Hertz
60.0 first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct third location and 9.000 maximum at 200 pct third location
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Frequency In Hertz
60.0 second location
-
Internal Trip Release Configuration
series trip first location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 first location
-
Trip Release Characteristic
time delay first location
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Internal Trip Release Configuration
series trip second location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
-
Nominal Thread Size
0.138 inches
-
Terminal Type And Quantity
9 threaded stud
-
Trip Release Characteristic
time delay second location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 second location
-
Internal Trip Release Configuration
series trip third location
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc fourth location
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Trip Release Characteristic
time delay third location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 third location
-
Trip Release Characteristic
instantaneous fourth location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 fourth location
-
Frequency In Hertz
60.0 third location
-
Internal Trip Release Configuration
shunt trip fourth location
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations and 25.0 amperes dc all locations
-
Thread Pitch Diameters
+0.1177/+0.1214 inches
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
-
Manual Actuator Type And Quantity
4 toggle
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Case Material
plastic
-
Body Length
2.490 inches nominal
-
Pole Quantity
4