AM2-Z159-1
Circuit Breakers
CIRCUIT BREAKER
AM2-Z159-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Operating Voltage Type And Rating Per Pole In Volts
35.0 dc second location
-
Pole Quantity
2
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc first location
-
Boss Height
0.150 inches nominal
-
Storage Type
general purpose warehouse
-
Criticality Code Justification
feat
-
Actuator Function
trip-reset
-
Test Data Document
80063-sm-a-838525 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Arc Quenching Method
magnetic blowout
-
Trip Release Characteristic
instantaneous second location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Manual Actuator Type And Quantity
2 toggle
-
Mounting Surface To Terminal End Distance
2.475 inches nominal
-
Inclosure Protection Type For Which Designed
shock resistant and hermetically sealed and vibration resistant
-
Thread Pitch Diameters
+0.1177/+0.1214 inches
-
Body Length
2.480 inches minimum and 2.500 inches maximum
-
Unpackaged Unit Weight
7.400 ounces
-
Terminal Type And Quantity
4 threaded stud
-
External Actuator Linkage Arrangement
one and two linked
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc all locations
-
Features Provided
high inrush protection
-
Case Material
plastic
-
Special Features
high inrush pole one only
-
Internal Trip Release Configuration
series trip all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Mounting Facility Type And Quantity
4 threaded hole
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct first location and 1.500 maximum at 200 pct first location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Trip Release Characteristic
time delay first location
-
Nominal Thread Size
0.138 inches
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc first location
-
Body Width
1.500 inches maximum