AM2-Z358-2
Circuit Breakers
CIRCUIT BREAKER
AM2-Z358-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
1.480 inches minimum and 1.520 inches maximum
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
2.850 inches maximum
-
Pole Quantity
2
-
Arc Quenching Method
magnetic blowout
-
Storage Type
general purpose warehouse
-
Operating Voltage Type And Rating Per Pole In Volts
107.0 dc second location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
-
Circuit Protection Type
overcurrent first location
-
Trip Release Characteristic
time delay first location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
2 toggle
-
External Actuator Linkage Arrangement
one and two linked
-
Internal Trip Release Configuration
series trip first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 maximum at 200 pct first location
-
Inclosure Protection Type For Which Designed
general purpose
-
Unpackaged Unit Weight
6.500 ounces
-
Body Style
8c multipole-multiple actuator type
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Mounting Facility Type And Quantity
4 clip
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac first location
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc second location
-
Trip Release Method
magnetic all locations
-
Trip Release Characteristic
instantaneous second location
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
Internal Trip Release Configuration
relay trip second location
-
Special Features
pole 2 circuit protection type is major voltage loss or no voltage
-
Frequency In Hertz
50.0 or 60.0
-
Terminal Type And Quantity
6 threaded stud