44-6-S-H-N-SI-300
Circuit Breakers
CIRCUIT BREAKER
44-6-S-H-N-SI-300
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Actuator Function
reset
-
Switch Terminal Type
tab, solder lug
-
Body Style
rectangular dimensional envelope
-
Trip Release Ambient Temp Rating
70.0 deg fahrenheit nominal single location
-
Reset Method
manual
-
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Maximum Continuous Load Current Rating Per Pole
300.0 amperes dc single location
-
Manual Actuator Type And Quantity
1 push button
-
Test Data Document
80063-sm-a-317335 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Switch Current Rating And Type In Amps
5.0 dc
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Overall Length
4.090 inches nominal
-
Switch Contact Arrangement
single pole, double throw
-
Pole Quantity
1
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 dc single location
-
Internal Trip Release Configuration
series trip single location
-
Unpackaged Unit Weight
30.000 ounces
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Switch Voltage Rating And Type In Volts
28.0 dc
-
Overall Width
3.940 inches nominal
-
Mounting Facility Type And Quantity
2 terminal
-
Terminal Type And Quantity
2 tab w/screw
-
Overall Height
1.580 inches nominal
-
Auxiliary Switch Function And Quantity
1 alarm
-
Trip Delay Time In Seconds Per Rated Continuous Current
100.000 nominal at 250 pct single location
-
Inclosure Protection Type For Which Designed
fungus resistant and corrosion resistant and humidity resistant
-
Switch Location And Position Designation
internal at pole one
-
Case Material
plastic