10080928-101

Circuit Breakers

CIRCUIT BREAKER

10080928-101

5925-01-146-1953

5925 - Circuit Breakers

Honeywell International Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location and 1.0 amperes dc single location

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Trip Release Ambient Temp Rating

    23.0 deg celsius nominal single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Width

    0.570 inches nominal

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Length

    1.140 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • End Item Identification

    4920-01-121-0603

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.790 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10.0 ac single location and 10.0 dc single location

  • Bushing Length

    0.250 inches nominal

  • Reset Method

    manual

  • Inclosure Protection Type For Which Designed

    moisture resistant and shock resistant and fungus resistant and hermetically sealed

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.375 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Thread Quantity Per Inch

    27

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.300 inches nominal

  • Internal Trip Release Configuration

    series trip single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...