AM2-Z159-10

Circuit Breakers

CIRCUIT BREAKER

AM2-Z159-10

5925-01-146-6691

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Special Features

    high inrush pole one only

  • Case Material

    plastic

  • Features Provided

    high inrush protection

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • External Actuator Linkage Arrangement

    one and two linked

  • Terminal Type And Quantity

    4 threaded stud

  • Unpackaged Unit Weight

    7.400 ounces

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Mounting Surface To Terminal End Distance

    2.475 inches nominal

  • Manual Actuator Type And Quantity

    2 toggle

  • Trip Release Characteristic

    instantaneous second location

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Test Data Document

    80063-sm-a-838525 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Body Width

    1.500 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc first location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay first location

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic all locations

  • Thread Quantity Per Inch

    32

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct first location and 11.000 maximum at 200 pct first location

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Boss Height

    0.150 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc all locations

  • Pole Quantity

    2

  • Operating Voltage Type And Rating Per Pole In Volts

    35.0 dc second location

  • Circuit Protection Type

    overcurrent all locations

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc all locations

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...