203-2-2-52-103-6-3-8

Circuit Breakers

CIRCUIT BREAKER

203-2-2-52-103-6-3-8

5925-01-146-9639

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 tab, solder lug

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Width

    0.920 inches nominal

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Mounting Facility Type And Quantity

    2 clip

  • Reset Method

    manual

  • Switch Terminal Type

    turret

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc single location

  • Ultimate Trip Time Per Pole In Seconds

    3.000 minimum single location and 60.000 maximum single location

  • Switch Current Rating And Type In Amps

    5.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc single location

  • Body Height

    1.770 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Switch Contact Arrangement

    single pole, double throw

  • Special Features

    handle equipped with internally mtd led,24-32 vdc,red; handle color black; body color gray

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Boss Height

    0.125 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct single location and 1.750 maximum at 400 pct single location and 0.020 minimum at 400 pct single location and 9.000 maximum at 200 pct single location and 0.005 minimum at 600 pct single location and 0.600 maximum at 600 pct

  • ~1

    single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...