GF1700-5C

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

GF1700-5C

5915-01-148-3083

5915 - Filters and Networks

Spectrum Control Inc.

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    3.370 inches nominal

  • Body Width

    3.120 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.854 inches minimum and 3.886 inches maximum

  • Vibration Resistance Range In Hertz

    10.0/ 500.0

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference .

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference .

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference .

  • Maximum Voltage Drop Per Function

    1.25 volts ac 2nd radio interference and 4.0 volts dc 2nd radio interference .

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Inclosure Type

    encased

  • Mounting Facility Type And Quantity

    6 unthreaded hole

  • Functional Terminal Type And Quantity

    3 threaded stud input .

  • Functional Terminal Type And Quantity

    3 threaded stud output .

  • Functional Terminal Type And Quantity

    4 threaded stud ground .

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 1st radio interference and 400.0 volts dc 1st radio interference .

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 2nd radio interference and 400.0 volts dc 2nd radio interference .

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 3rd radio interference and 400.0 volts dc 3rd radio interference .

  • Overall Length

    4.370 inches nominal

  • Body Height

    1.500 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.125 inches minimum and 1.155 inches maximum

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference .

  • Load Impedance Per Function

    50.0 ohms 1st radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference .

  • Maximum Voltage Drop Per Function

    1.25 volts ac 1st radio interference and 4.0 volts dc 1st radio interference .

  • Maximum Voltage Drop Per Function

    1.25 volts ac 3rd radio interference and 4.0 volts dc 3rd radio interference .

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Maximum Temp Rise

    25.0 deg celsius

  • Body Material

    metal

  • Maximum Dielectric Withstanding Dc Voltage

    1.5 kilovolts at sea level

  • Style Designator

    5 rectangular terminal/terminals on opposite surfaces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...