RF9088-4B

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

RF9088-4B

5915-01-148-3296

5915 - Filters and Networks

Rfi Corporation

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Output Terminal Identification

    m24308/2-5

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Body Height

    1.760 inches maximum

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Maximum Voltage Drop Per Function

    500.0 millivolts ac 1st radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Overall Length

    8.190 inches nominal

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 4th radio interference 4th function

  • Unpackaged Unit Weight

    2.700 pounds

  • Output Terminal Manufacturer Code

    81349

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 5th radio interference 5th function

  • Maximum Voltage Drop Per Function

    500.0 millivolts ac 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 6th radio interference 6th function

  • Maximum Voltage Drop Per Function

    500.0 millivolts ac 3rd radio interference

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Functional Terminal Type And Quantity

    1 connector, receptacle output 2nd function

  • Special Features

    9 functions

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Inclosure Type

    encased

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Maximum Dielectric Withstanding Dc Voltage

    600.0 volts at sea level

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    4.620 inches minimum and 4.630 inches maximum

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.870 inches minimum and 4.880 inches maximum

  • Body Surface Treatment

    tin

  • Operating Voltage Rating And Type Per Function

    168.0 volts ac 1st radio interference 1st function

  • Operating Temp Range

    -55.0/+95.0 deg celsius

  • Mounting Facility Type And Quantity

    5 captive screws

  • Operating Voltage Rating And Type Per Function

    168.0 volts ac 2nd radio interference 2nd function

  • Maximum Voltage Drop Per Function

    45.0 millivolts dc 4th radio interference

  • Body Width

    4.205 inches nominal

  • Operating Current Rating Per Function In Amps

    15.0 3rd radio interference

  • Input Terminal Manufacturer Code

    96906

  • Operating Current Rating Per Function In Amps

    15.0 2nd radio interference

  • Nominal Thread Size

    0.164 inches

  • Mounting Facility Screw Thread Series Designator

    unc

  • Input Terminal Identification

    ms27656t23b21p

  • Operating Current Rating Per Function In Amps

    15.0 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Body Material

    aluminum

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Maximum Voltage Drop Per Function

    45.0 millivolts dc 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Operating Current Rating Per Function In Amps

    3.0 6th radio interference

  • Maximum Temp Rise

    35.0 deg celsius

  • Maximum Voltage Drop Per Function

    45.0 millivolts dc 5th radio interference

  • Operating Current Rating Per Function In Amps

    3.0 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Operating Current Rating Per Function In Amps

    3.0 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Body Length

    5.500 inches maximum

  • Operating Voltage Rating And Type Per Function

    168.0 volts ac 3rd radio interference 3rd function

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Functional Terminal Type And Quantity

    1 connector, receptacle input 1st function

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...