946082-2
Coils and Transformers
TRANSFORMER,POWER
946082-2
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reliability Indicator
not established
-
Winding Operating Voltage
200.00 ac volts minimum and 240.00 ac volts maximum
-
Winding Operating Voltage
7.60 dc volts minimum and 12.70 dc volts maximum
-
Cognizant Service
usaf
-
Terminal Type And Quantity
13 wire lead
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.000 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.810 inches nominal
-
Mounting Slot Width
0.216 inches nominal
-
Input-Output Phase Relationship
single phase to single phase
-
Winding Shielding Method
internal shield grounded to inclosure
-
Body Width
3.840 inches maximum
-
Mounting Method
slot
-
Winding Tap Location
center tap
-
Winding Operating Current
1.0 amperes dc maximum
-
Winding Operating Voltage
15.50 dc volts nominal and 18.30 dc volts nominal and 23.50 dc volts nominal and 30.00 dc volts nominal
-
Frequency Rating
47.0 hertz minimum and 63.0 hertz maximum
-
Body Length
3.960 inches nominal
-
Body Height
4.630 inches maximum
-
Inclosure Type
fully inclosed
-
Mounting Facility Quantity
4
-
Winding Function And Quantity
2 primary and 2 secondary
-
Winding Tap Location
multiple taps w/center tap
-
Winding Operating Current
0.1 amperes dc maximum