Technical Characteristics

  • Body Style

    11b multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Width

    3.000 inches nominal

  • Boss Height

    0.250 inches nominal

  • Pole Quantity

    3

  • Features Provided

    adjustable trip release

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Auxiliary Switch Function And Quantity

    2 control

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +1175.0/+2350.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    60.000 minimum at 300 pct and 120.000 maximum at 300 pct all locations

  • Switch Terminal Type

    wire lead

  • Frequency In Hertz

    60.0

  • Body Length

    11.000 inches nominal

  • Body Width

    9.000 inches nominal

  • Body Height

    4.625 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    9.875 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    9.875 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    3.000 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    20

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac and 100.0 amperes dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    450.0 ac and 120.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    20000.0 ac and 15000.0 dc all locations

  • Nominal Thread Size

    0.250 inches

  • Switch Location And Position Designation

    internal at pole one and internal at pole two

  • Inclosure Protection Type For Which Designed

    general purpose

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Switch Voltage Rating And Type In Volts

    115.0 ac and 120.0 dc

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...