860-013586Y-00

Circuit Breakers

CIRCUIT BREAKER

860-013586Y-00

5925-01-149-2957

5925 - Circuit Breakers

Snydergeneral Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Slot Width

    0.164 inches nominal

  • Body Length

    5.844 inches nominal

  • Body Width

    3.096 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.032 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • Fragility Factor

    moderately rugged

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    6 threaded hole and 6 slot

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac .

  • Circuit Protection Type

    overcurrent .

  • Trip Release Method

    magnetic-hydraulic .

  • Trip Release Characteristic

    time delay .

  • Main Contact Tripping Mechanism Type

    trip free

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip .

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Frequency In Hertz

    50.0 or 60.0

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 screw

  • Body Style

    caaql 8c

  • Center To Center Distance Between Terminals Parallel To Length

    3.546 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Boss Height

    0.218 inches nominal

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Features Provided

    high inrush protection

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac .

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac .

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    11.000 minimum at 200 pct and 125.000 maximum at 200 pct .

  • Unpackaged Unit Weight

    2.000 pounds

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...