AP1-76-3

Circuit Breakers

CIRCUIT BREAKER

AP1-76-3

5925-01-149-6959

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    0.625 inches maximum

  • Case Material

    metal

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Frequency In Hertz

    400.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Storage Type

    general purpose warehouse

  • Iii Special Handling Feature

    magnetic

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    hermetically sealed and

  • Inclosure Protection Type For Which Designed

    shock resistant and

  • Inclosure Protection Type For Which Designed

    vibration resistant

  • Frequency In Hertz

    50.0 or

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    2 wire hook

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Body Style

    2a single pole type

  • Bushing Length

    0.380 inches maximum

  • Body Length

    1.500 inches maximum

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    50.0 milliamperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Reset Method

    manual

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...