AP-112-1RC-42-1251
Circuit Breakers
CIRCUIT BREAKER
AP-112-1RC-42-1251
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Case Material
metal
-
Center To Center Distance Between Terminals Parallel To Width
0.610 inches minimum and 0.640 inches maximum
-
Nonturn Device Location
at 3 oclock and at 9 oclock
-
Nonturn Device Radius
0.610 inches minimum and 0.640 inches maximum
-
Nonturn Device Diameter
0.235 inches minimum and 0.265 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Mounting Surface To Terminal End Distance
1.780 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Special Handling Feature
magnetic
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
1.25 amperes ac all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Internal Trip Release Configuration
series trip all locations
-
Nominal Thread Size
0.375 inches
-
Switch Location And Position Designation
internal at pole two
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct
-
Inclosure Protection Type For Which Designed
hermetically sealed and shock resistant and vibration resistant
-
Switch Terminal Type
wire hook
-
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
-
Frequency In Hertz
400.0 all locations
-
Terminal Type And Quantity
6 wire hook
-
Thread Pitch Diameters
0.3503 to 0.3537 inches
-
Body Style
1b multipole-single actuator type
-
Bushing Length
0.380 inches maximum
-
Body Length
1.562 inches maximum
-
Body Width
1.937 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.860 inches minimum and 0.890 inches maximum
-
Fragility Factor
moderately rugged
-
Pole Quantity
3
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Characteristic
time delay all locations
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole two
-
Auxiliary Switch Function And Quantity
1 alarm
-
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
-
Unpackaged Unit Weight
5.400 ounces
-
Thread Series Designator
unef