APGN-66-1-62-252

Circuit Breakers

CIRCUIT BREAKER

APGN-66-1-62-252

5925-01-150-0253

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.480 inches minimum and 0.510 inches maximum

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.515 inches minimum and 1.545 inches maximum

  • Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.500 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct and 20.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    moisture resistant and salt spray proof and shock resistant and vibration resistant

  • Body Style

    multipole-single actuator type

  • Body Width

    1.515 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Nonturn Device Location

    at 12 oclock

  • Nonturn Device Radius

    0.641 inches minimum and 0.671 inches maximum

  • Nonturn Device Length

    0.115 inches minimum and 0.145 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Trip Release Method

    magnetic

  • Internal Trip Release Configuration

    series trip

  • Frequency In Hertz

    50.0 or b60.0

  • Test Data Document

    97953-1a7864 drawing

  • Thread Series Designator

    un

  • Terminal Type And Quantity

    4 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...