127-0352
Circuit Breakers
CIRCUIT BREAKER
127-0352
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Surface To Terminal End Distance
2.210 inches nominal
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Inclosure Protection Type For Which Designed
moisture resistant
-
Circuit Protection Type
overcurrent all locations
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac second location
-
Pole Quantity
2
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Manual Actuator Type And Quantity
2 toggle
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct second location and 1.800 maximum at 200 pct second location
-
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc first location
-
Body Width
1.500 inches nominal
-
External Actuator Linkage Arrangement
one and two linked
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location
-
Internal Trip Release Configuration
relay trip first location
-
Case Material
plastic
-
Boss Height
0.130 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Frequency In Hertz
50.0 second location or 60.0 second location
-
Reset Method
manual
-
Internal Trip Release Configuration
series trip w/auxiliary load terminal second location
-
Terminal Type And Quantity
7 quick disconnect, male
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc first location
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Mounting Facility Type And Quantity
4 threaded hole
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
50.0 milliamperes dc first location
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Trip Release Characteristic
instantaneous first location
-
Center To Center Distance Between Terminals Parallel To Length
1.560 inches nominal
-
Nominal Thread Size
0.138 inches
-
Trip Release Characteristic
time delay second location