SM-A-838216-6
Filters and Networks
FILTER,BAND PASS
SM-A-838216-6
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Band Width Per Function
14.752 kilohertz 1st band pass and 15.344 kilohertz 1st band pass
-
Specified Frequencies Of Discrimination Per Function
34.928 kilohertz 4th band pass and 35.28 kilohertz 4th band pass and 36.72 kilohertz 4th band pass and 37.072 kilohertz 4th band pass
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Load Impedance Per Function
100.0 kilohms 1st band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 5th band pass and 30.0 minimum 5th band pass and 3.0 maximum 5th band pass and 30.0 minimum 5th band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 4th band pass
-
Body Length
3.035 inches maximum
-
Style Designator
rectangular terminal/terminals on one surface
-
Unpackaged Unit Weight
6.500 ounces
-
Specified Frequencies Of Discrimination Per Function
24.096 kilohertz 3rd band pass and 23.168 kilohertz 3rd band pass and 22.928 kilohertz 3rd band pass and 24.352 kilohertz 3rd band pass
-
Reference Frequency Per Function
21.376 single radio interference two phase to two phase
-
Frequency Band Width Per Function
40.784 kilohertz 5th band pass and 42.416 kilohertz 5th band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 1st band pass and 3.0 maximum 1st band pass and 30.0 minimum 1st band pass and 30.0 minimum 1st band pass
-
Load Impedance Per Function
100.0 kilohms 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 5th band pass
-
Reference Frequency Per Function
36.0 single radio interference hertz
-
Functional Terminal Type And Quantity
1 pin ground 3rd function
-
Frequency Band Width Per Function
23.168 kilohertz 3rd band pass and 24.096 kilohertz 3rd band pass
-
Load Impedance Per Function
100.0 kilohms 3rd band pass
-
Frequency Band Width Per Function
35.28 kilohertz 4th band pass and 36.72 kilohertz 4th band pass
-
Specified Frequencies Of Discrimination Per Function
14.608 kilohertz 1st band pass and 14.752 kilohertz 1st band pass and 15.344 kilohertz 1st band pass and 15.52 kilohertz 1st band pass
-
Load Impedance Per Function
100.0 kilohms 4th band pass
-
Operating Temp Range
-29.0/+85.0 deg celsius
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum 2nd band pass and 3.0 maximum 2nd band pass and 3.0 maximum 2nd band pass and 30.0 minimum 2nd band pass
-
Source Impedance Rating Per Function
1.0 kilohms 1st band pass
-
Load Impedance Per Function
100.0 kilohms 5th band pass
-
Mounting Facility Type And Quantity
5 plug-in
-
Overall Height
0.850 inches maximum
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum 3rd band pass and 3.0 maximum 3rd band pass and 3.0 maximum 3rd band pass and 30.0 minimum 3rd band pass
-
Functional Terminal Type And Quantity
5 pin output 2nd function
-
Body Height
0.580 inches maximum
-
Source Impedance Rating Per Function
1.0 kilohms 2nd band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.624 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.500 inches nominal
-
Source Impedance Rating Per Function
1.0 kilohms 3rd band pass
-
Reference Frequency Per Function
41.6 single radio interference three phase to two phase
-
Body Width
1.875 inches maximum
-
Reference Frequency Per Function
15.056 single radio interference pulses per second
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Source Impedance Rating Per Function
1.0 kilohms 4th band pass
-
Functional Terminal Type And Quantity
2 pin input 1st function
-
Source Impedance Rating Per Function
1.0 kilohms 5th band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum 4th band pass and 3.0 maximum 4th band pass and 3.0 maximum 4th band pass and 30.0 minimum 4th band pass
-
Reference Frequency Per Function
23.632 single radio interference two phase to three phase
-
Inclosure Type
encased
-
Specified Frequencies Of Discrimination Per Function
20.736 kilohertz 2nd band pass and 20.944 kilohertz 2nd band pass and 21.792 kilohertz 2nd band pass and 22.032 kilohertz 2nd band pass
-
Specified Frequencies Of Discrimination Per Function
42.416 kilohertz 5th band pass and 40.352 kilohertz 5th band pass and 40.784 kilohertz 5th band pass and 42.848 kilohertz 5th band pass
-
Frequency Band Width Per Function
20.944 kilohertz 2nd band pass and 21.792 kilohertz 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 3rd band pass
-
Body Surface Treatment
tin