222-10NC1-2221148
Switches
SWITCH,PRESSURE
222-10NC1-2221148
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Voltage Rating In Volts
115.0 ac at sea level second voltage
-
Contact Load Current Rating
9.6 amperes inductive load fourth voltage
-
Features Provided
electrical access port
-
Distance Between Mounting Facility Centers
5.250 inches nominal
-
Body Height
2.750 inches nominal
-
Pressure Switch Type
gage
-
Contact Voltage Rating In Volts
550.0 dc at sea level third voltage
-
Nominal Thread Size
0.250 inches single pressure connection
-
Mounting Facility Pattern
two position in-line
-
Contact Action Stimulus
increase
-
Nonpile-Up Contact Arrangement
1 pole, single throw, normally closed, momentary action
-
Contact Adjustability
deactuation point adjustable and actuation point adjustable
-
Mounting Method
bracket and unthreaded hole
-
Contact Load Current Rating
16.0 amperes inductive load second voltage
-
Thread Series Designator
npt single pressure connection
-
Contact Voltage Rating In Volts
115.0 dc at sea level fourth voltage
-
Style Designator
rectangular w/bracket
-
Contact Load Current Rating
2.0 amperes inductive load third voltage
-
Contact Adjustment Type
external deactuation point screw and external actuation point screw
-
Contact Voltage Rating In Volts
550.0 ac at sea level first voltage
-
Unthreaded Mounting Hole Diameter
0.281 inches nominal
-
Overall Height
3.500 inches nominal
-
Overall Width
2.625 inches nominal
-
Contact Load Current Rating
3.2 amperes inductive load first voltage
-
Terminal Type
screw
-
Media For Which Designed
gas or liquid
-
Pressure Connector Type
flared, threaded external single connection