SM-A-838523-3

Circuit Breakers

CIRCUIT BREAKER

SM-A-838523-3

5925-01-152-2402

5925 - Circuit Breakers

Us Army Communications &

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.900 minimum at 200 pct and 10.000 maximum at 200 pct

  • Switch Terminal Type

    tab,solder lug

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Thread Pitch Diameters

    p0.1177/p0.1214 inches

  • Body Style

    single pole type

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Switch Contact Arrangement

    single pole,double throw

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Mounting Surface To Terminal End Distance

    3.268 inches minimum and 3.392 inches maximum

  • Pole Quantity

    1

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    dustproof

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Body Length

    2.480 inches minimum and 2.520 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Fragility Factor

    moderately rugged

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...