JC-D2A
Relays and Solenoids
RELAY,ELECTROMAGNETIC
JC-D2A
Leach International Corporation
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Main Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac lamp load and 5.0 amperes dc lamp load
-
Overall Length
1.718 inches nominal
-
Overall Width
1.625 inches nominal
-
Terminal Type And Quantity
3 wire hook energizing element and contacts
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac motor load and 10.0 amperes dc motor load
-
Frequency In Hertz
400.0 nominal
-
Time Delay
0.01 seconds nominal fixed operate and release time
-
Main Contact Load Current Rating At Maximum Rated Voltage
25.0 amperes ac resistive load and 25.0 amperes dc resistive load
-
Coil Quantity
1
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.421 inches nominal single mounting facility
-
Overall Height
0.515 inches nominal
-
Main Contact Load Current Rating At Maximum Rated Voltage
15.0 amperes ac inductive load and 12.0 amperes dc inductive load
-
Duty Type
continuous
-
Mounting Facility Pattern
in-line single mounting facility
-
Terminal Type And Quantity
2 pin dummy
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts teardrop, two holes type 4f single winding
-
Nonpile-Up Main Contact Arrangement
1 pole, double throw, both positions maintained
-
Mounting Facility Type And Quantity
2 unthreaded hole single mounting facility
-
Environmental Protection
hermetic
-
Winding Dc Resistance Rating
320.0 ohms nominal single winding
-
Nominal Operating Current Rating And Type
100.0 milliamperes dc single winding
-
Winding Quantity
1
-
Unthreaded Mounting Hole Diameter
0.150 inches nominal single mounting facility