10B68
Filters and Networks
FILTER,BAND PASS
10B68
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Source Impedance Rating Per Function
1.0 kilohms 1st band pass
-
Overall Height
0.850 inches maximum
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
Principal Circuitry Type Per Function
inductance-capacitance 1st band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.375 inches nominal
-
Inclosure Type
hermetically sealed
-
Body Height
0.580 inches maximum
-
Source Impedance Rating Per Function
1.0 kilohms 2nd band pass
-
Reference Frequency Per Function
350.0 single high pass pulses per second
-
Source Impedance Rating Per Function
1.0 kilohms 3rd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Frequency Band Width Per Function
340.00 hertz 1st band pass and 360.00 hertz 1st band pass
-
Frequency Band Width Per Function
416.00 hertz 2nd band pass and 448.00 hertz 2nd band pass
-
Frequency Band Width Per Function
470.00 hertz 3rd band pass and 511.00 hertz 3rd band pass
-
Operating Temp Range
-29.0/+85.0 deg celsius
-
Load Impedance Per Function
100.0 kilohms 3rd band pass
-
Specified Frequencies Of Discrimination Per Function
360.00 hertz 1st band pass and 340.00 hertz 1st band pass and 330.00 hertz 1st band pass and 370.00 hertz 1st band pass
-
Functional Terminal Type And Quantity
1 pin ground 3rd function
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.750 inches nominal
-
Reference Frequency Per Function
432.0 single high pass two phase to two phase
-
Special Features
three filtered functions
-
Load Impedance Per Function
100.0 kilohms 2nd band pass
-
Unpackaged Unit Weight
3.500 ounces
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd band pass
-
Specified Frequencies Of Discrimination Per Function
410.00 hertz 2nd band pass and 416.00 hertz 2nd band pass and 448.00 hertz 2nd band pass and 455.00 hertz 2nd band pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Functional Terminal Type And Quantity
3 pin output 2nd function
-
Body Length
2.905 inches maximum
-
Body Material
metal
-
Load Impedance Per Function
100.0 kilohms 1st band pass
-
Reference Frequency Per Function
490.0 single high pass two phase to three phase
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Body Surface Treatment
tin
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 3rd band pass
-
Mounting Facility Type And Quantity
12 pin
-
Functional Terminal Type And Quantity
1 pin input 1st function
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 2nd band pass and 3.0 minimum 1st band pass and 3.0 minimum 3rd band pass and 30.0 maximum 1st band pass
-
Body Width
2.280 inches maximum
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 maximum 3rd band pass
-
Specified Frequencies Of Discrimination Per Function
511.00 hertz 3rd band pass and 470.00 hertz 3rd band pass and 462.00 hertz 3rd band pass and 520.00 hertz 3rd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 maximum 2nd band pass