SM-A-838216-10

Filters and Networks

FILTER,BAND PASS

SM-A-838216-10

5915-01-152-7225

5915 - Filters and Networks

Us Army Communications &

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Temp Range

    -29.0/+85.0 deg celsius

  • Reference Frequency Per Function

    1.1 single radio interference three phase to two phase

  • Source Impedance Rating Per Function

    1.0 kilohms 1st band pass

  • Load Impedance Per Function

    100.0 kilohms 5th band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th band pass

  • Body Length

    4.030 inches maximum

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st band pass

  • Overall Height

    0.779 inches nominal

  • Functional Terminal Type And Quantity

    5 pin output 2nd function

  • Unpackaged Unit Weight

    4.250 ounces

  • Frequency Band Width Per Function

    926.00 hertz 2nd band pass and 957.00 hertz 2nd band pass

  • Inclosure Type

    hermetically sealed

  • Source Impedance Rating Per Function

    1.0 kilohms 2nd band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.500 inches nominal

  • Body Height

    0.560 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 3rd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 1st band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 4th band pass

  • Frequency Band Width Per Function

    1.081 kilohertz 5th band pass and 1.119 kilohertz 5th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 5th band pass

  • Frequency Band Width Per Function

    1.033 kilohertz 4th band pass and 1.068 kilohertz 4th band pass

  • Specified Frequencies Of Discrimination Per Function

    926.00 hertz 2nd band pass and 957.00 hertz 2nd band pass and 916.00 hertz 2nd band pass and 967.00 hertz 2nd band pass

  • Body Surface Treatment

    tin

  • Reference Frequency Per Function

    900.0 single high pass pulses per second

  • Reference Frequency Per Function

    1.0 single radio interference two phase to three phase

  • Specified Frequencies Of Discrimination Per Function

    1.119 kilohertz 5th band pass and 1.081 kilohertz 5th band pass and 1.069 kilohertz 5th band pass and 1.132 kilohertz 5th band pass

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Special Features

    five filtered functions

  • Specified Frequencies Of Discrimination Per Function

    1.033 kilohertz 4th band pass and 1.068 kilohertz 4th band pass and 1.021 kilohertz 4th band pass and 1.08 kilohertz 4th band pass

  • Specified Frequencies Of Discrimination Per Function

    885.00 hertz 1st band pass and 876.00 hertz 1st band pass and 915.00 hertz 1st band pass and 924.00 hertz 1st band pass

  • Load Impedance Per Function

    100.0 kilohms 1st band pass

  • Specified Frequencies Of Discrimination Per Function

    983.00 hertz 3rd band pass and 1.017 kilohertz 3rd band pass and 970.00 hertz 3rd band pass and 1.031 kilohertz 3rd band pass

  • Load Impedance Per Function

    100.0 kilohms 3rd band pass

  • Mounting Facility Type And Quantity

    14 pin

  • Body Material

    metal

  • Load Impedance Per Function

    100.0 kilohms 4th band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 4th band pass

  • Style Designator

    rectangular terminal/terminals on one surface

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd band pass

  • Load Impedance Per Function

    100.0 kilohms 2nd band pass

  • Frequency Band Width Per Function

    983.00 hertz 3rd band pass and 1.017 kilohertz 3rd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 5th band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.750 inches nominal

  • Reference Frequency Per Function

    941.0 single high pass two phase to two phase

  • Functional Terminal Type And Quantity

    1 pin ground 3rd function

  • Frequency Band Width Per Function

    885.00 hertz 1st band pass and 915.00 hertz 1st band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 4th band pass and 3.0 minimum 5th band pass and 3.0 minimum 1st band pass and 3.0 minimum 3rd band pass and 3.0 minimum 2nd band pass and 30.0 maximum 5th band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 2nd band pass

  • Reference Frequency Per Function

    1.05 single radio interference hertz

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 3rd band pass

  • Body Width

    2.280 inches maximum

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 4th band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd band pass

  • Functional Terminal Type And Quantity

    1 pin input 1st function

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 3rd band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...