SM-A-838216-11

Filters and Networks

FILTER,BAND PASS

SM-A-838216-11

5915-01-152-7226

5915 - Filters and Networks

Us Army Communications &

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 2nd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 3rd band pass

  • Body Width

    2.280 inches maximum

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd band pass

  • Functional Terminal Type And Quantity

    1 pin input 1st function

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 5th band pass

  • Specified Frequencies Of Discrimination Per Function

    1.173 kilohertz 1st band pass and 1.233 kilohertz 1st band pass and 1.185 kilohertz 1st band pass and 1.246 kilohertz 1st band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 3rd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 1st band pass and 3.0 minimum 2nd band pass and 3.0 minimum 3rd band pass and 3.0 minimum 4th band pass and 3.0 minimum 5th band pass and 30.0 maximum 4th band pass

  • Body Surface Treatment

    tin

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Specified Frequencies Of Discrimination Per Function

    1.452 kilohertz 3rd band pass and 1.524 kilohertz 3rd band pass and 1.436 kilohertz 3rd band pass and 1.54 kilohertz 3rd band pass

  • Special Features

    five filtered functions

  • Reference Frequency Per Function

    1.318 single radio interference two phase to two phase

  • Load Impedance Per Function

    100.0 kilohms 1st band pass

  • Body Material

    metal

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 4th band pass

  • Frequency Band Width Per Function

    1.185 kilohertz 1st band pass and 1.233 kilohertz 1st band pass

  • Style Designator

    rectangular terminal/terminals on one surface

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd band pass

  • Frequency Band Width Per Function

    1.452 kilohertz 3rd band pass and 1.524 kilohertz 3rd band pass

  • Load Impedance Per Function

    100.0 kilohms 2nd band pass

  • Reference Frequency Per Function

    2.25 single radio interference hertz

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 5th band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.750 inches nominal

  • Functional Terminal Type And Quantity

    1 pin ground 3rd function

  • Load Impedance Per Function

    100.0 kilohms 3rd band pass

  • Specified Frequencies Of Discrimination Per Function

    2.549 kilohertz 5th band pass and 2.522 kilohertz 5th band pass and 2.651 kilohertz 5th band pass and 2.678 kilohertz 5th band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.500 inches nominal

  • Body Height

    0.560 inches nominal

  • Frequency Band Width Per Function

    2.205 kilohertz 4th band pass and 2.295 kilohertz 4th band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th band pass

  • Reference Frequency Per Function

    2.6 single radio interference three phase to two phase

  • Source Impedance Rating Per Function

    1.0 kilohms 3rd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 1st band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 4th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 5th band pass

  • Frequency Band Width Per Function

    1.28 kilohertz 2nd band pass and 1.357 kilohertz 2nd band pass

  • Reference Frequency Per Function

    1.488 single radio interference two phase to three phase

  • Mounting Facility Type And Quantity

    14 pin

  • Load Impedance Per Function

    100.0 kilohms 4th band pass

  • Operating Temp Range

    -29.0/+85.0 deg celsius

  • Source Impedance Rating Per Function

    1.0 kilohms 1st band pass

  • Load Impedance Per Function

    100.0 kilohms 5th band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th band pass

  • Body Length

    4.030 inches maximum

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st band pass

  • Overall Height

    0.779 inches nominal

  • Specified Frequencies Of Discrimination Per Function

    2.205 kilohertz 4th band pass and 2.183 kilohertz 4th band pass and 2.295 kilohertz 4th band pass and 2.317 kilohertz 4th band pass

  • Functional Terminal Type And Quantity

    5 pin output 2nd function

  • Reference Frequency Per Function

    1.209 single radio interference pulses per second

  • Unpackaged Unit Weight

    4.250 ounces

  • Inclosure Type

    hermetically sealed

  • Specified Frequencies Of Discrimination Per Function

    1.267 kilohertz 2nd band pass and 1.28 kilohertz 2nd band pass and 1.357 kilohertz 2nd band pass and 1.37 kilohertz 2nd band pass

  • Frequency Band Width Per Function

    2.549 kilohertz 5th band pass and 2.651 kilohertz 5th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 2nd band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...