10B69
Filters and Networks
FILTER,BAND PASS
10B69
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Specified Frequencies Of Discrimination Per Function
785.00 hertz 4th band pass and 747.00 hertz 4th band pass and 755.00 hertz 4th band pass and 794.00 hertz 4th band pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Specified Frequencies Of Discrimination Per Function
604.00 hertz 2nd band pass and 595.00 hertz 2nd band pass and 636.00 hertz 2nd band pass and 645.00 hertz 2nd band pass
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd band pass
-
Load Impedance Per Function
100.0 kilohms 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 5th band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.750 inches nominal
-
Specified Frequencies Of Discrimination Per Function
674.00 hertz 3rd band pass and 712.00 hertz 3rd band pass and 682.00 hertz 3rd band pass and 720.00 hertz 3rd band pass
-
Functional Terminal Type And Quantity
1 pin ground 3rd function
-
Body Height
0.560 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance 5th band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 1st band pass and 30.0 maximum 1st band pass
-
Specified Frequencies Of Discrimination Per Function
558.00 hertz 1st band pass and 551.00 hertz 1st band pass and 582.00 hertz 1st band pass and 589.00 hertz 1st band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 5th band pass and 30.0 maximum 5th band pass
-
Source Impedance Rating Per Function
1.0 kilohms 3rd band pass
-
Reference Frequency Per Function
852.0 single high pass three phase to two phase
-
Frequency Band Width Per Function
835.00 hertz 5th band pass and 869.00 hertz 5th band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Source Impedance Rating Per Function
1.0 kilohms 4th band pass
-
Source Impedance Rating Per Function
1.0 kilohms 5th band pass
-
Reference Frequency Per Function
770.0 single high pass hertz
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 3rd band pass and 30.0 maximum 3rd band pass
-
Reference Frequency Per Function
697.0 single high pass two phase to three phase
-
Body Width
2.280 inches maximum
-
Frequency Band Width Per Function
682.00 hertz 3rd band pass and 712.00 hertz 3rd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 4th band pass and 30.0 maximum 4th band pass
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd band pass
-
Load Impedance Per Function
100.0 kilohms 3rd band pass
-
Mounting Facility Type And Quantity
14 pin
-
Load Impedance Per Function
100.0 kilohms 4th band pass
-
Operating Temp Range
-29.0/+85.0 deg celsius
-
Source Impedance Rating Per Function
1.0 kilohms 1st band pass
-
Load Impedance Per Function
100.0 kilohms 5th band pass
-
Principal Circuitry Type Per Function
inductance-capacitance 4th band pass
-
Body Length
4.030 inches maximum
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
Principal Circuitry Type Per Function
inductance-capacitance 1st band pass
-
Overall Height
0.779 inches nominal
-
Reference Frequency Per Function
570.0 single high pass pulses per second
-
Functional Terminal Type And Quantity
5 pin output 2nd function
-
Unpackaged Unit Weight
4.250 ounces
-
Reference Frequency Per Function
620.0 single high pass two phase to two phase
-
Inclosure Type
hermetically sealed
-
Source Impedance Rating Per Function
1.0 kilohms 2nd band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.500 inches nominal
-
Functional Terminal Type And Quantity
1 pin input 1st function
-
Specified Frequencies Of Discrimination Per Function
826.00 hertz 5th band pass and 869.00 hertz 5th band pass and 835.00 hertz 5th band pass and 878.00 hertz 5th band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 3rd band pass
-
Frequency Band Width Per Function
604.00 hertz 2nd band pass and 636.00 hertz 2nd band pass
-
Body Surface Treatment
tin
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Special Features
five filtered functions
-
Frequency Band Width Per Function
558.00 hertz 1st band pass and 582.00 hertz 1st band pass
-
Load Impedance Per Function
100.0 kilohms 1st band pass
-
Body Material
metal
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 4th band pass
-
Frequency Band Width Per Function
755.00 hertz 4th band pass and 785.00 hertz 4th band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 2nd band pass and 30.0 maximum 2nd band pass