SM-A-838216-9

Filters and Networks

FILTER,BAND PASS

SM-A-838216-9

5915-01-153-2618

5915 - Filters and Networks

Filter Research Corp

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Specified Frequencies Of Discrimination Per Function

    785.00 hertz 4th band pass and 747.00 hertz 4th band pass and 755.00 hertz 4th band pass and 794.00 hertz 4th band pass

  • Style Designator

    rectangular terminal/terminals on one surface

  • Specified Frequencies Of Discrimination Per Function

    604.00 hertz 2nd band pass and 595.00 hertz 2nd band pass and 636.00 hertz 2nd band pass and 645.00 hertz 2nd band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd band pass

  • Load Impedance Per Function

    100.0 kilohms 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 5th band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.750 inches nominal

  • Specified Frequencies Of Discrimination Per Function

    674.00 hertz 3rd band pass and 712.00 hertz 3rd band pass and 682.00 hertz 3rd band pass and 720.00 hertz 3rd band pass

  • Functional Terminal Type And Quantity

    1 pin ground 3rd function

  • Body Height

    0.560 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 1st band pass and 30.0 maximum 1st band pass

  • Specified Frequencies Of Discrimination Per Function

    558.00 hertz 1st band pass and 551.00 hertz 1st band pass and 582.00 hertz 1st band pass and 589.00 hertz 1st band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 5th band pass and 30.0 maximum 5th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 3rd band pass

  • Reference Frequency Per Function

    852.0 single high pass three phase to two phase

  • Frequency Band Width Per Function

    835.00 hertz 5th band pass and 869.00 hertz 5th band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 4th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 5th band pass

  • Reference Frequency Per Function

    770.0 single high pass hertz

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 3rd band pass and 30.0 maximum 3rd band pass

  • Reference Frequency Per Function

    697.0 single high pass two phase to three phase

  • Body Width

    2.280 inches maximum

  • Frequency Band Width Per Function

    682.00 hertz 3rd band pass and 712.00 hertz 3rd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 4th band pass and 30.0 maximum 4th band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd band pass

  • Load Impedance Per Function

    100.0 kilohms 3rd band pass

  • Mounting Facility Type And Quantity

    14 pin

  • Load Impedance Per Function

    100.0 kilohms 4th band pass

  • Operating Temp Range

    -29.0/+85.0 deg celsius

  • Source Impedance Rating Per Function

    1.0 kilohms 1st band pass

  • Load Impedance Per Function

    100.0 kilohms 5th band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th band pass

  • Body Length

    4.030 inches maximum

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st band pass

  • Overall Height

    0.779 inches nominal

  • Reference Frequency Per Function

    570.0 single high pass pulses per second

  • Functional Terminal Type And Quantity

    5 pin output 2nd function

  • Unpackaged Unit Weight

    4.250 ounces

  • Reference Frequency Per Function

    620.0 single high pass two phase to two phase

  • Inclosure Type

    hermetically sealed

  • Source Impedance Rating Per Function

    1.0 kilohms 2nd band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.500 inches nominal

  • Functional Terminal Type And Quantity

    1 pin input 1st function

  • Specified Frequencies Of Discrimination Per Function

    826.00 hertz 5th band pass and 869.00 hertz 5th band pass and 835.00 hertz 5th band pass and 878.00 hertz 5th band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 3rd band pass

  • Frequency Band Width Per Function

    604.00 hertz 2nd band pass and 636.00 hertz 2nd band pass

  • Body Surface Treatment

    tin

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Special Features

    five filtered functions

  • Frequency Band Width Per Function

    558.00 hertz 1st band pass and 582.00 hertz 1st band pass

  • Load Impedance Per Function

    100.0 kilohms 1st band pass

  • Body Material

    metal

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 4th band pass

  • Frequency Band Width Per Function

    755.00 hertz 4th band pass and 785.00 hertz 4th band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 2nd band pass and 30.0 maximum 2nd band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...